Although the belt dryer is a relatively efficient and energy-saving dryer, there is a fault in the actual operation. What we do is to find out the cause of the fault and eliminate it. Let the belt dryer do our best for us. service. Therefore, when customers choose the belt dryer, pay attention to the configuration of the dryer. The selection of the filter on the belt dryer should be compatible with the dryer tooth passage and the hole diameter. Generally, the filter diameter of the filter is dry. The machine can be inserted into the channel or the aperture is 0.2 times. What are the common faults in the use of belt dryers? How to solve them? How to carry out maintenance? Kewei professionals introduce you to the following points:
     1. Check the gas source triple piece before starting the machine, drain the water and ensure sufficient oil level.
     2. Ensure that the dryer equipment is well grounded and the temperature gauge on the equipment should be metrologically verified.
     3. Inspect and maintain the parts, such as lubricating the bearings, adjusting the pulleys, checking the electrical lines, the rocker arm of the door, the pipe joints, etc. and fixing them.
     4, the raw material fire failure, may be the design of the dryer equipment, or the raw materials can not be sucked, causing fire in the dryer. In addition, it may also be caused by human factors, such as the forced heating of a dryer that is too small to achieve a drying effect. At this time, it is best to replace the dryer equipment to check whether the dryer is installed correctly, whether it leaks or increases the wind pressure. Use the dryer properly and carefully increase the temperature of the dryer to avoid ignition.
     5, there is a problem of raw materials drying at one time, which is mainly caused by the dryer is too small or the dryer is not used properly. In addition, wind network wind pressure and flow calculation errors can also cause such failures. The drying equipment can be replaced or re-modified, or the manufacturer is required to recalculate the wind pressure, flow and other changes. If it is caused by improper operation, the operator will operate in strict accordance with the instructions.
     6. Ensure that the fixing bolts of the machine base are not loose, the support springs are tightly connected, and the control of the computer board, the wind wheel and the heat exchanger have good flexibility.
     7. Keep the equipment clean, wipe the equipment daily, and clean the fluff inside the dust box to ensure ventilation. Regularly open the rear cover to clean the inside of the device.

Relevant articles
Related products
  • DWC Dehydrated Vegetables Belt Dryer
    DWC Dehydrated Vegetables Belt Dryer
  • DW Multi-belt Dryer
    DW Multi-belt Dryer
  • DW Single-belt Dryer
    DW Single-belt Dryer
  • Closed loop spray dryer CCSD series
    Closed loop spray dryer CCSD series
  • Fluidized bed spray dryer FSD series
    Fluidized bed spray dryer FSD series
  • Production Air Spray Dryer FNSD Series
    Production Air Spray Dryer FNSD Series
  • Production pressure spray dryer PNSD
    Production pressure spray dryer PNSD
  • Production of universal centrifugal spray dryer RSD series
    Production of universal centrifugal spray dryer RSD series
Top